Security Command R500 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Sistemas de segurança - controlo de acesso Security Command R500. Security Command R500 User guide [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Hitachi Storage Command Suite
Hitachi Device Manager Software
SMI-S Provider Installation and User Guide
F
AST
F
IND
L
INK
S
Document Organization
Software Version
Getting Help
Contents
MK-96HC138-06
Vista de página 0
1 2 3 4 5 6 ... 61 62

Resumo do Conteúdo

Página 1

Hitachi Storage Command Suite Hitachi Device Manager Software SMI-S Provider Installation and User Guide FASTFIND LINKS Document Organiza

Página 2

Document Conventions This document uses the following typographic conventions: Convention Description Bold Indicates text on a window, other than th

Página 3 - Contents

Convention for Storage Capacity Values Storage capacity values for logical devices are calculated based on the following values: 1 KB (kilobyte) = 1,0

Página 4

xii Preface Hitachi Device Manager SMI-S Provider Installation and User Guide

Página 5 - Contents v

1 Overview and Setup of CIM/WBEM 1-1 Hitachi Device Manager SMI-S Provider Installation and User Guide Overview and Setup of CIM/WBEM This chapte

Página 6

Device Manager and CIM/WBEM Device Manager supports WBEM defined by the standards-setting organization DMTF. WBEM is a standard proposed by the DMTF f

Página 7 - Preface

From a CIM client, you can specify a namespace by using the following procedure: • Specify the SMI-S version. Specify root/smis/smisxx (xx is an abbr

Página 8 - Release Notes

CIM/WBEM Features of Device Manager CIM/WBEM of Device Manager provides the four features specified in SMI-S: • Objection operation feature • Indica

Página 9 - Referenced Documents

Preparing to Use the CIM/WBEM Features CIM/WBEM features are disabled by default in the Device Manager settings. To use them, you must specify the fol

Página 10 - Document Conventions

If any service program is running (normally, another WBEM service program) that is using the same port to be used by an object operation feature, the

Página 11 - Comments

Note: When upgrading Device Manager from version 4.2 or earlier to 4.3 or later, check the httpsd.conf file. If it contains coding that enables SSL

Página 12

ii Hitachi Device Manager SMI-S Provider Installation and User Guide Copyright © 2008 Hitachi Data Systems Corporation, ALL RIGHTS RESERVED Notice: N

Página 13

Setting up the Ports Used by CIM/WBEM Features Opening and Closing Ports According to the Communication Type Ports can be opened or closed according t

Página 14 - Device Manager and CIM/WBEM

Changing the Port Number In the initial state, the port numbers used by the CIM/WBEM features are as follows: • HTTP port number: 5988 • HTTPS port

Página 15 - Root/smis/current 1.2.0

Setting up the Properties File Used by the CIM/WBEM Feature When executing CIM, you must set up the properties files for the Device Manager server, th

Página 16 - – Cancellation of a path

server.cim.http.port To use non-SSL for the CIM interface, specify the HTTP port number. Default: 5988 server.cim.https.port To use SSL for the CIM in

Página 17 - Feature Port Number Used

The jserver.properties File This property file sets up the operating environment for the WBEM Service. It is stored in the following directory when De

Página 18 - # /etc/init.d/init.wbem stop

Setting the Service Discovery Feature To use the service discovery feature of Device Manager, you need the following prerequisite software: • In Wind

Página 19 - \httpsd\conf\httpsd.conf

3. Register the SLP service as a Windows service. Execute the following command: > slpd -install To automatically start the service when Windows

Página 20 - – In Windows:

4. Start the SLP daemon by restarting Solaris or executing the following command: # /etc/init.d/slpd start If Device Manager is uninstalled, stop or

Página 21

Starting and Stopping the Service Discovery Feature In Windows To manually start the SLP service, perform either of the following procedures: • From

Página 22 - Executing CIM

In Linux To manually start the SLP daemon, execute the following command: installation-directory-for-the-Device-Manager-server/HiCommandServer/wsi/bi

Página 23

Contents iii Hitachi Device Manager SMI-S Provider Installation and User Guide Contents Preface...

Página 24 - The jserver.properties File

Acquiring Performance Information Device Manager can obtain performance information of a storage subsystem using the CIM interface. The following stor

Página 25 - In Windows

Figure 1-2 Example System Configuration for Collecting Performance Data of a Storage Subsystem This section describes the system configuration that

Página 26 - In Solaris

Even if you use a machine, which is different from the management server, for the host to acquire performance information, the OS for the host that ac

Página 27 - In Linux

Preparations in the host that acquires performance information Configure the settings shown below for the performance information-acquiring host: To c

Página 28

Preparations in the Device Manager server For the Device Manager server property, specify the name of the host from which performance information is a

Página 29 - Notes on using OpenSLP

Table 1-5 Values to Specify in the perf_cmddev.properties File Setting Item Value Specify one of the following depending on the type of the target s

Página 30 - Acquisition Feature

The parameters for the perf_findcmddev command are described below. If you specify no parameter, multiple parameters, or upper-case parameters, the me

Página 31 - Data of a Storage Subsystem

Acquiring Performance Data for Hitachi SMS, Hitachi AMS/WMS, Thunder 9500 or Thunder 9200 This section describes the settings required to acquire perf

Página 32 - TagmaStore USP

hdvmmodpolluser Command Format The hdvmmodpolluser command is stored in the following location: • Windows: installation-folder-for-the-Device-Manager

Página 33

User Permissions for Using CIM/WBEM Features The following table shows the user permissions for using CIM/WBEM features, based on the Device Manager p

Página 34

propdir ... 1-12 logdir ...

Página 35 - • Solaris or Linux:

Security Settings for CIM/WBEM Functionality CIM/WBEM functionality supports SSL communication for the following functions: • Object operations In th

Página 36

Modifying the Keystore File for Object Operations Following is the default location of the keystore file used for CIMOM object operations (the keystor

Página 37 - Thunder 9500 or Thunder 9200

4. Modify the MOF file (WBEMSolutions_CIMXMLSObjectManagerAdapter_instances.mof). Specify in the MOF file the keystore password that was encrypted in

Página 38 - • Solaris:

Specifying Two-Way Authentication for the Object Operation You can use HiKeytool to set up two-way authentication for object operations. First Setup P

Página 39 - Legend:

4. Stop the Device Manager server as indicated in the displayed message. – Windows: Select Start, All Programs, Hitachi Storage Command Suite, Devic

Página 40 - • Event indication

7. Enter the alias, the truststore password, and the client authentication file name. Enter the client authentication file name by absolute path. An

Página 41 - – Solaris or Linux:

Specifying Two-Way Authentication for Event Indications This section describes how to set up two-way authentication for event indications. First Setup

Página 42

3. Stop the Device Manager server: – In Windows, select Start, All Programs, Hitachi Storage Command Suite, Device Manager, then Stop Server. – In

Página 43

8. If (Current setting: SSL without two-way authentication) appears at item 2 in the SMI-S main panel, type 2. If (Current setting:SSL with two-way a

Página 44

11. In the SMI-S main panel, enter 4. This option starts processing to import the client authentication file to the truststore file for event indicati

Página 45

Contents v Hitachi Device Manager SMI-S Provider Installation and User Guide Troubleshooting ...

Página 46

Disabling Two-way Authentication Use HiKeytool for disabling two-way authentication for object operations or event indications. 1. Open a command pro

Página 47

5. Enter 1. The mofcomp command is executed and the MOF file is compiled. You are returned to the SMI-S main panel when the mofcomp command has compl

Página 48

Authenticating File Operations This section describes the following operations required for SSL-encrypted communication between the Device Manager ser

Página 49

Creating a Keystore File To create a keystore file: 1. Execute the following command: – Windows: hcmdskeytool -genkey -keystore keystore-filename -s

Página 50

Exporting an Authentication File from a Keystore File To export an authentication file from a keystore file: 1. Execute the following command: – Win

Página 51

Overview and Setup of CIM/WBEM 1-43 Hitachi Device Manager SMI-S Provider Installation and User Guide

Página 53 - Creating a Keystore File

2 Troubleshooting 2-1 Hitachi Device Manager SMI-S Provider Installation and User Guide Troubleshooting This chapter provides contact information f

Página 54

2-2 Troubleshooting Hitachi Device Manager SMI-S Provider Installation and User Guide Calling the Hitachi Data Systems Support Center If you need to c

Página 55

Acronyms and Abbreviations Acronyms-1 Hitachi Device Manager SMI-S Provider Installation and User Guide Acronyms and Abbreviations CIM Common In

Página 57 - Troubleshooting

Acronyms-2 Acronyms and Abbreviations Hitachi Device Manager SMI-S Provider Installation and User Guide

Página 58 - • United States:

Hitachi Device Manager SMI-S Provider Installation and User Guide

Página 59 - Acronyms and Abbreviations

MK-96HC138-06 Hitachi Data Systems Corporate Headquarters 750 Central Expressway Santa Clara, California 95050-2627 U.S.A. Phone: 1 408 970 1000 www.

Página 60

Preface vii Hitachi Device Manager SMI-S Provider Installation and User Guide Preface This manual describes the Hitachi Device Manager CIM/WBEM ins

Página 61

Intended Audience This manual is intended for users who manage systems containing storage subsystems (disk array devices). Such users should have a ba

Página 62 - MK-96HC138-06

Preface ix Hitachi Device Manager SMI-S Provider Installation and User Guide Document Revision Level Revision Date Description MK-96HC138-00 June

Comentários a estes Manuais

Sem comentários