R5INIT Initialisation Function Module 4-3
4.2.2 Output Parameter
Parameter Att. Description
P5 W Result
Fig. 4-3 R5INIT — Output parameter
This parameter provides the PLC program with the result of the initialisa-
tion and signals any faults.
Code Explanation
0000H Initialisation ended without fault
0001H No CXN matching Parameter 0 available
0002H No CXN matching Parameter 1 available
0004H No CXN matching Parameter 2 available
0008H No CXN matching Parameter 3 available
0010H No CXN matching Parameter 4 available
0020H No free memory for memory management list
0021H No data-field address in the memory management list
0030H Communications fault on the CXN
0031H Communications fault on the ZS
Fig. 4-4 R5INIT — Error codes