37883 Station The server TaskLRN is not sent immediately when scripting the Value of an alphanumeric,
exposing a timing hole when writing script which pulses the Value
38056 Station When a system time change occurs CommsEngine.exe can go 100% CPU and leave Station
unusable
38382 Station When printing a DSP chart, the horizontal axis is not displayed. This occurs in print preview
as well as the actual print out
38292 Station With Danish (or other European country) Regional Settings zooming causes drawing
problems
34688 Station Station configuration Auxiliary Setup file will not work if entered manually - must use
Browse
38179 Station Need the ability for a display to specify faceplate parameters before invoking a faceplate
38182 Station Invoking multiple faceplates at the same instant can cause Station to become unusable
38445 Station The @P string does not successfully invoke a screen print
38523 Station The Icons on the toolbar are being displayed with less colors/lower resolution
38700 Station Indicator can cause Station to unexpectedly terminate
38725 Station The chart can cause Station to unexpectedly terminate
40496 Station In rare case it is possible to trap Station by using the scroll button on an HMIWeb trend
40682 Station IKB Service fails to work in a multi station environment when operating the IKB leds
40781 Station Shapes which are rotated can sometimes display unrotated (DSP displays)
41323 Station IKB keys launch two pages when used in a Popup window to invoke a page change
41618 Station IKB Enter key stops working when a message box is invoked in a popup window
41649 Station Alphanumeric with hexadecimal format may not display negative values correctly
41759 Station Custom DSP displays flash if large scripts or bitmaps exist
42015 Station Display problem after minimizing station
42025 Station Data Subscription on HMIWeb pages can become corrupt if faceplates are pushpinned
42077 Station Linked shapes do not print correctly
42466 Station OnPageComplete not fired on page if HVG object has data applied and then removed
42258 Station Operators can access local file systems via the Command Zone
43190 Station Can no longer use the arrows keys to find and select previously entered data in command
zone
43903 Station Station crashes/hangs when using F5 key and performing operator commands